System type: Open System
Plate types: 96 well plates
Wells Type: U, V and Flat bottom wells
Operating Modes:
- Absorbance
- Quantitative
- Qualitative
- Semi-Quantitative
- Kinetic Mode
Measurement Modes: Continuous / Step
Shaking Modes: Three Linear Speeds - Low, Medium and Fast. Time duration can be set
Wavelength Selection:
- Monochromatic
- Bi-Chromatic
- Multi-Chromatic* (Maximum 4)
Calculation Modes:
- Non-linear Standard
- Cut-off
- Index Formula
- Column Subtraction
- Linear Regression
- Point to Point
- Cubic Spline
- Linear – Log
Blank Options:
- Blank, Control, Assay
- Validation equations
- Against Air, Well
- Plate, Column, Column-mean
- Row, Row mean
Number of programmable standards / calibrators: Up to 10 standards /test Storage/ display/ printing of multi standard curves and cut-off equations for all parameters
Test Programs: 100 totally “open” Test Programs
Photometer:
- Measuring system: 8-Channel optical system
- Lamp Source: Tungsten Halogen with Lamp saver function
- Wavelength Range: 400 to 750 nm
- Standard Filters: 405 nm, 450 nm, 492 nm, 630 nm (Optional two filters 578 nm, 700 nm), 10 nm Band Pass
- Dynamic Range: 0.0 ~4.0 OD
- Photometric accuracy: < 1% at 2.5 OD at 450 nm
- Photometric resolution: 0.001 OD
- Linearity: <1% at 2.5 OD at 450 nm
Measurement Time:
SPEED : 8 Seconds single wavelength
NORMAL : 17 Seconds single wavelength
Display:
High resolution Graphics LCD 320x240 pixels, LED Backlight, View area: 120x92 mm
Keyboard: Rugged waterproof & membrane panel
PC Communication: USB Based
Protocol compatible with Eli-LIMS and TNW
Built-in Thermal Printer: Built in High resolution, 384 dots per line, thermal Type with full graphics facility printer and option for connecting External Parallel Printer (or USB Printer using External Adaptor).
Computer interfacing Software: Windows Based Software Eli-LIMS with data managemenOptional Windows Based Software with data management capabilities to store patient results, store/display calibration curve /QC curves.
Reports on internal and external printers: Report generation for last 7000 Sample’s is viewed/printed/stored.
Lab name in Print-out
Lab name in Display
Collated reports
Print-out of Normal Range along with the result (on external printer only).
Graphs can be printed on Thermal Printer
Sorted by:
Date
I.D.
Both by Date & I.D.
Test
Plate ID
Online Help: At each step on-line help in each menu. Beeps and online instructions on erroneous entry. Special HELP key on keypad.
Operating Temperature: 20˚ C to 40˚ C
Storage Temperature: -10˚ C to 50˚ C
Humidity: Max. 80% RH, non- condensing
Power Supply: 16 V - 24.5 V DC using External Auto ranging SMPS adapter
115/230VAC ±10%, 50/60Hz., Max. 90 Watt. (CE & UL certified)
Dimension: 502 mm X 369 mm X 216 mm
Weight: 7 Kg